2 20-750-UFB-1 Universal Feedback Encoder Option Module (revision 1.015) 2. Use the or key to scroll to the drive port where the UFB module is installed (for example, Port 4, 5 or 6). Press the key to display its last-viewed folder. Safe Stop 1 SS2 Safe Stop 2. SOS Safe Operational Stop. Integrated Safety Functions Opt. Module Product Overview for 20-750-S4 SLS Safely-Limited Speed SDI Safe Direction SBC Safe Brake Control SLP Safely-Limited Position Preliminary mock-up (PCB final version is red) (Additional Safety Functions under consideration).PF755T only. Catalog Number 20-750-S1 Safety Reference Manual Original Instructions. Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to.
Hi All, I am looking for user manual for 20-750-UFB-1 Universal Feedback Module for Power Flex 755 drive. We have a problem here. One of the servo motor was burnt and we replaced it with spare one but drive is not detecting encoder (feed back loss). Fault is 'voltage source to encoder is out of range'. But when I connect other motor (not suitable for the machine) drive shows OK. But with spare motor drive is faulted. I want to know exact procedure for setting up encoder card and servo motor. Please send me a link or send to my e-mail id [email protected] Thanks & regards, Shree
These instructions cover the installation of the option modules listed below. For instructions on installing Network Communication option modules, refer to publication
750COM-IN002
.
Compatible Ports
Option Module Installation
Using 20-750-S1 with 20-750-DENC-1
20-750-APS
20-750-S
20-750-S1
20-750-2262C-2R
20-750-2263C-1R2T
20-750-2262D-2R
20-750-1132C-2R
20-750-1133C-1R2T
20-750-1132D-2R
20-750-ENC-1
20-750-DENC-1
20-750-UFB-1
20-750-ATEX
Option Module Cat. No. 20-750-
PowerFlex 753 Drives
PowerFlex 755 Drives
Frame 1 Ports
Frame 2…7 Ports
Frame 1 Ports
Frame 2…10 Ports
APS
See Page 2
See Page 2
See Page 2
Yes
No
No
No
No
2262C-2R, 2263C-1R2T, 2262D-2R
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1132C-2R, 1133C-1R2T, 1132D-2R
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1132C-2R, 1133C-1R2T, 1132D-2R with 20-750-ATEX installed
(1)
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
No
No
Yes
Yes
ENC-1
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
UFB-1
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
No
Yes
Yes
Yes
S
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
S1
(2)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
DENC-1
No
Yes
Yes
Yes
Yes
Yes
20 750 Ufb 1
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(1) For detailed instructions on installation of 11-Series I/O with the ATEX option module, refer to the PowerFlex 750-Series ATEX User Manual, publication
750-UM003
.
(2) See Using 20-750-S1 with 20-750-DENC-1.
0.45 N•m (4.0 lb•in)
20-750-S1
20-750-DENC-1
IMPORTANT: When a Safe Speed Monitor option (20-750-S1) is used with a Dual Incremental Encoder option (20-750-DENC-1) both modules must be installed on the same backplane (ports 6, 5, 4).
IMPORTANT: Only one safety option module can be installed at a time. Multiple safety options or duplicate safety option installations are not supported.